Oписание продукта

OMRON  K3MA-F-A2  AC100-240V  Digital panel meter,,rate meter, frequency meter

 

This digital penel  meter Using backlight double color LED (red/green), cathode LCD display, to achieve a high degree of visibility. With the function of comparing output , comparing preset value,,according to the comparison of the output t action, can change display colors, green to  red(oppositely available )
Even thougth is  far away from the device, also can by displaying a color change,  can master operating condition of the  device easily

If don’t have the comparing output fuction, can choose the current color red or green , it  depend on the the display purpose and usage of the production site

 

 

 

Supply voltage

AC 100 to 240V (50/60Hz)

Operating voltage range

85% to 110% of the rated power supply voltage

Power consumption

6 VA max (max. load)

External power supply

12 VDC 40 mA

Pulse measurement input (Input type)

NPN input/voltage pulse input

Pulse measurement input (No-voltage contact) 

Input frequency range 30 Hz max. ON/OFF pulse width of 15 ms min.

Pulse measurement input (Voltage pulse)

Input frequency range 5kHz; ON/OFF pulse width of 90 us min.
(Voltage level: ON voltage:4.5 to 30 V; OFF voltage :0 to 2 V; input impedance:10 k Ohm)

Pulse measurement input (Open collector)

Input frequency range 5kHz; ON/OFF pulse width of 90 us min.

Pulse measurement input (Accuracy)

+/- 0.1% +/- 1 digit

Connectable sensors

ON residual voltage: 2.5 V max.
OFF leakage current: 0.1 mA max.
Load current: Must have a switching capacity of 15 mA or higher. Must be able to properly switch load currents of 5 mA or less.

Display method

7-segment digital display

Digits

5 digits

Character height

14.2 mm (green/red)

Zero suppress

Leading zeros are not displayed.

Decimal point display position

Selected with parameters

Filters function

Average processing

Display function

Display Color Selection, Display auto-return

Outputs function

Comparative Output Pattern, Startup Compensation Timer

Ambient temperature

Operating: -10 to +55 CEL
Storage: -25 to +65 CEL
(with no icing or condensation)

Ambient humidity

Operating: 25 to 85 %RH
Storage: 25 to 85 %RH

Display range

-19999 to 99999

A/D conversion method 

Cycle measurement

Comparative output response time

750ms max

Insulation resistance

20 MOhm min.(at 500 VDC) between external terminals and case. Insulation provided between inputs, outputs and power supply.

Dielectric strength

2,000 VAC 1min (between external terminals and case)

Noise immunity

+/- 1,500V at power supply terminals in normal or common mode(waveform with 1-ns rising edge and pulse width of 1us/100 ns)

Vibration resistance

Malfunction: Frequency: 10 to 55 Hz; Acceleration: 50m/s2 10 sweeps of 5 min each in X Y and Z directions

Shock resistance

Malfunction: 150 m/s2 3 times each on 3 axes 6 directions

Degree of protection

Front panel: NEMA4X for indoor use(equivalent to IP66)
Rear case: IP20
Terminals: IP00 + finger protection(VDE0106/100)

Memory protection

EE-PROM(non-volatile memory) Number of rewrites: 100,000

Safety standards

UL61010-1, CSA C22.2 No.61010-1-04, EN61010-1(IEC61010-1) 

Applicable standard (EC Directive (EMC Directive))

Standard No.: EN61326
EMI: EN61326 industrial applications
Emission Enclosure: CISPR 11 Group1 Class A:CISPRL 16-1/-2
Emission AC mains: CISPR 11 Group1 Class A:CISPRL 16-1/-2
EMS: EN61326 industrial applications
Immunity ESD: EN61000-4-2 (4 kV (contact) 8 kV (in air))
Immunity RF-interference: EN61000-4-3 (10 V/m sine wave amplitude modulation)
Immunity Fast Transient Burst: EN61000-4-4 (2 kV (power line) 1 kV (I/O signal line))
Immunity Surge: EN61000-4-5 (1 kV with line(power line), 2 kV with ground(power line))
Immunity Conducted Disturbance: EN61000-4-6 (3 V (0.15 to 80 MHz))
Voltage Dips and interruptions immunity: EN61000-4-11 (0.5 cycle 0/180 degrees 100% (rated voltage))

Net Weight

Approx. 300 g